Normally Open Switch

Normally Closed Switch

• Key-On, Engine Off
• System Mode= “Stopped”

Does DTC 524

reset ?

Intermittent Problem

No

• Key Off
• Disconnect harness from Oil Pressure switch
• Check continuity through switch to ground.

Yes

Is switch closed?

• Oil Pressure circuit shorted-to-ground in harness
• Faulty ECM

• Faulty Oil Pressure Switch (short circuit)
• Faulty engine oiling system (verify with

mechanical gauge)

No

Yes

• Key-On, Engine Off
• System Mode= “Stopped”

Does DTC 524

reset ?

Intermittent Problem

No

• Key Off
• Disconnect harness from Oil Pressure switch
• Check continuity through switch to ground.

Yes

Is switch open?

• Oil Pressure circuit shorted-to-ground in harness
• Faulty ECM

• Faulty Oil Pressure Switch (short circuit)
• Faulty engine oiling system (verify with

mechanical gauge)

No

Yes