SECTION 6 - JLG CONTROL SYSTEM

6-22

– JLG Lift –

3121290

LOAD SENSOR:
17*
* Only visible if Load
Sensor Menu selection
is not 0 and under cer-
tain market selections.
* Certain market selec-
tions will limit load sen-
sor options.

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those
which use the Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

FUNCTION CUTOUT:
18*
* Only visible under cer-
tain market selections.
* Certain market selec-
tions will limit function
cutout options or alter
default setting.

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive & steer cutout above elevation.

DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.

0

GROUND ALARM:
19*
* Certain market selec-
tions will alter default
setting.

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

3

DRIVE:
20*
* Only visible under cer-
tain model selections.

0

1

2

4WD: Four wheel drive.

2WD: Two wheel drive.

2WD W/2-SPEED: Two wheel drive with 2-speed valve.

0

DISPLAY UNITS:
21*
* Certain market selec-
tions will alter default
setting.

0

1

IMPERIAL: Deg F, PSI, LBS.

METRIC: DEG C, KPA, KGS.

0

Table 6-3. Machine Configuration Programming Information Software Version P6.1 to Present