Adjust parameters, Adjust parameters -5 – JLG 450A_AJ Series II Service Manual User Manual

Page 315

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121290

– JLG Lift –

6-5

Press ENTER

to select the ACCESS LEVEL menu.

Using UP

or DOWN

arrow keys, enter first digit of

the password, 3.

Using RIGHT

arrow key, position cursor right one space

to enter the second digit of the password.

Use UP

or DOWN

arrow key to enter second digit

of the password which is 33271.

When correct password is displayed, press ENTER

. The

access level displays the following if password was entered
correctly:

MENU:

ACCESS LEVEL 1

Repeat above steps if correct access level is not displayed or
you can not adjust personality settings.

Adjust Parameters

Once you have gained access to level 1, and a personality item

is selected, press UP

or DOWN

arrow keys to

adjust its value, for example:

DRIVE:

ACCEL 1.0S

There will be a minimum and maximum for the value to
ensure efficient operation. The Value will not increase if the UP

arrow is pressed at maximum value or decrease if the

DOWN

arrow is pressed at minimum value for any per-

sonality. If value does not change when pressing up and down
arrows, check access level is at access level 1.

Advertising