Table 6-6. Help Fault Codes, Displayed Faults, and Descriptions

Flash Code

Fault Displayed on Analyzer

Description

Priority

None

No flash code indicated for the following help messages. They indi-
cate a possible problem if vehicle is not operating as expected.

1

EVERYTHING OK

“Normal” help message in platform mode

GROUND MODE OK

“Normal” help message in ground mode

FSW OPEN

A drive or boom function has been selected but footswitch is open.

RUNNING AT CREEP – CREEP
SWITCH OPEN

All function speeds limited to creep because creep switch is open.

RUNNING AT CREEP – TILTED AND
ABOVE ELEVATION

All boom function speeds limited to creep because vehicle is tilted
and above elevation.

RUNNING AT CUTBACK – OUT OF
TRANSPORT POSITION

Drive speed is limited to “ELEVATED MAX” because vehicle is out of
transport position.

CHASSIS TILT SENSOR OUT OF
RANGE

Chassis tilt sensor has indicated a tilt angle greater than 19 degrees
for more than 4 seconds. Not reported during 2 second power-up.

LOAD SENSOR READING UNDER
WEIGHT

Load sensor is reading 20% or more under calibrated zero point. This
fault may occur if basket is resting on ground. Not reported during 2
second power-up.

ENVELOPE ENCROACHED –
HYDRAULICS SUSPENDED

Machines with envelope control ONLY. System has detected an
envelope violation

OVER MOMENT – HYDRAULICS
SUSPENDED

Only occurs on machines with moment control. System has
detected an over moment violation.

UNDER MOMENT – HYDRAULICS
SUSPENDED

Machines with moment control ONLY. System has detected an
under moment violation.

1/1

Flash code 1/1 indicates a “sleep” mode.
NOT REQUIRED

2/1

Flash code 2/1 indicates problems with footswitch.

2

FSW FAULTY

Two footswitch inputs have read the same state for more than one
second. An EMS cycle is required.

KEYSWITCH FAULTY

Platform and ground modes selected simultaneously

2/2

Flash code 2/2 indicates problems with drive & steer selection.
Except where noted, these faults are not reported during 2 sec-
ond power-up sequence.

3

DRIVE LOCKED – JOYSTICK MOVED
BEFORE FOOTSWITCH

Drive selected before and during footswitch closure. Can be
reported during power-up sequence.

FSW INTERLOCK TRIPPED

Footswitch closed for seven seconds with no function selected. Can
be reported during power-up sequence.

STEER LOCKED – SELECTED
BEFORE FOOTSWITCH

Steer was selected before and during footswitch closure.

STEER SWITCHES FAULTY

Both steer switches are active at same time.

D/S JOY. OUT OF RANGE LOW

Resistive joysticks: These faults do not occur.

D/S JOY. OUT OF RANGE LOW

Resistive joysticks: These faults do not occur.

D/S JOY. OUT OF RANGE HIGH

Resistive joysticks: These faults do not occur if Vref voltage is below
8.1 volts. If Vref is above 7.7 volts, Vref is operating out of tolerance or
a short to battery has occurred.