JLG 450A_AJ Series II Service Manual User Manual
Page 326

SECTION 6 - JLG CONTROL SYSTEM
6-16
– JLG Lift –
3121290
SWING
ACCELeration
0.0 to 5.0s
2.0
DECELeration
0.0 to 3.0s
1.5
MINimum LEFT speed
1 to 50%
32
MAXimum LEFT speed
1 to 100%
66
CREEP maximum LEFT speed
1 to 65%
51
MINimum RIGHT speed
1 to 50%
38
MAXimum RIGHT speed
1 to 100%
61
CREEP maximum RIGHT speed
1 to 65%
51
Engine RPM
800 to 2900
1400
TELESCOPE MAIN
ACCELeration
0.0 to 5.0
2.0
DECELeration
0.0 to 3.0
1.0
MINimum IN speed
1 to 65%
27
MAXimum IN speed
1 to 100%
40
MINimum OUT speed
1 to 65%
27
MAXimum OUT speed
1 to 100%
37
Engine RPM
800 to 2900
1800
PLATFORM LEVEL
ACCELeration
0.0 to 5.0
2.5
DECELeration
0.0 to 3.0
0.5
MINimum UP speed
1 to 65%
15
MAXimum UP speed
1 to 100%
25
MlNimum DOWN speed
1to 65%
15
MAXimum DOWN speed
1 to 100%
25
Engine RPM
800 to 2900
1500
PLATFORM ROTATE
ACCELeration
0.1 to 5.0
2.0
DECELeration
0.1 to 3.0
0.5
MlNimum LEFT speed
1 to 65%
15
MAXimum LEFT speed
1 to 100%
30
MINimum RIGHT speed
1 to 65%
15
MAXimum RIGHT speed
1 to 100%
30
Engine RPM
800 to 2900
1500
Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS