Plugs/fittings size & torque -62 – JLG 450A_AJ Series II Service Manual User Manual

Page 302

Advertising
background image

SECTION 5 - HYDRAULICS

5-62

– JLG Lift –

3121290

Figure 5-109. Plugs/Fittings Size & Torque

#

Plug/

Fitting

Torque

lb. ft.

Nm

1

Servo Gauge Port M4

N/A

N/A

2

11/16

20-35

27-47

3

9/16

70-100

95-135

4

Case Drain Port L1

N/A

N/A

5

Charge Pressure Gauge M3

N/A

N/A

6

Charge Pump Inlet Port S

85

115

7

Case Drain Port L2

N/A

N/A

8

Port N

N/A

N/A

9

System Gauge M1 & M2

N/A

N/A

10

System Ports A&B

85

115

11

11/16

20-35

27-47

12

9/16

70-100

95-135

13

11/16

20-35

27-47

14

Servo Gauge M5

N/A

N/A

15

11/16

20-35

27-47

Advertising