Shaft seal and shaft replacement, Shaft seal and shaft replacement -63, Shaft seal removal -63 – JLG 450A_AJ Series II Service Manual User Manual

Page 303: Installation of shaft seal -63

Advertising
background image

SECTION 5 - HYDRAULICS

3121290

– JLG Lift –

5-63

5.

Install new O-ring on valve plug. Reinstall poppet,
spring, and plug (with shims and O-ring) into pump
housing. Torque to 40-100 ft-lb (55-135 Nm).

SCREW ADJUSTABLE STYLE

1.

Mark plug, lock nut, and housing to maintain original
adjustment before removing screw adjustable relief valve
plug. Loosen lock nut (1-1/16" Hex) and remove plug (8
mm Int. Hex). Remove O-ring from plug.

2.

Remove spring and poppet from housing.

3.

Inspect poppet and mating seat in housing for damage
or foreign material.

4.

Install new O-ring on valve plug. Reinstall poppet and
spring. Reinstall plug and lock nut. Torque to 34 - 42 ft-lb
(47-57 Nm), aligning marks made at disassembly.

5.

Check and adjust charge pressure if necessary. For screw
adjustable “anti-stall” charge relief valves, an approxi-
mate rule of thumb is 2.8 bar/quarter turn (40 psi/quar-
ter turn).

6.

Measure charge pressure (port M3) with pump in stroke.
Charge pressure should level off when relief setting is
reached.

Shaft Seal and Shaft Replacement

A lip type shaft seal is used in Series 42 pumps. Seal and shaft
can be replaced without major unit disassembly. Replacement
generally requires removing pump from machine.

Figure 5-112. Installation of Shaft Seal

1. Lock Nut

2. O-Ring

3. Plug

4. Spring T-Seal

5. Poppet

Figure 5-110. Screw Adjustable Charge Relief Valve

Components

1. Retaining Ring

2. Seal Carrier Assembly

Figure 5-111. Shaft Seal Removal

1. O-Ring

2. Seal

3. Seal Carrier

4. Use sealant on outside diameter
5. Inside Lip (face down)

6. Press Seal to Bottom of Seal Carrier

Advertising