Flash code 8/4 indicates problems with the envelope system.
Only occur on machines with envelope control.

10

BOOM ANGLE SENSOR DISAGREE-
MENT

The boom angle sensors are reporting angles that differ too greatly.
An EMS cycle is required.

BOOM LENGTH SWITCH FAILED

The boom length switch inputs are reporting the same state. An EMS
cycle is required.

BOOM LENGTH SWITCH/SENSOR
DISAGREEMENT

The boom length switch and sensor differ in their reports of
extended or retracted. An EMS cycle is required.

BOOM LENGTH SENSOR NOT
DETECTING LENGTH CHANGE

The boom length sensor has not detected a change in length while
the user is commanding telescope. An EMS cycle is required.

BOOM LENGTH SENSOR OUT OF
RANGE HIGH

Indicates that the voltage for the boom length sensor is above the
expected range.

BOOM LENGTH SENSOR OUT OF
RANGE LOW

Indicates that the voltage for the boom length sensor is below the
expected range.

BOOM LENGTH SENSOR VALUE
OUT OF RANGE HIGH

Indicates the length reported for the boom length sensor is above
the expected range. An EMS cycle is required.

BOOM LENGTH SENSOR VALUE
OUT OF RANGE LOW

Indicates the length reported for the boom length sensor is below
the expected range. An EMS cycle is required.

BOOM ANGLE SENSOR #1 COMMU-
NICATIONS FAULT

Boom angle sensor #1 lost communications with the BLAM. An EMS
cycle is required.

BOOM ANGLE SENSOR #2 COMMU-
NICATIONS FAULT

Boom angle sensor #2 lost communications with the BLAM. An EMS
cycle is required.

ANGLE SENSOR #1 INVALID ANGLE An EMS cycle is required.

ANGLE SENSOR #2 INVALID ANGLE An EMS cycle is required.

WRONG TELE RESPONSE

The boom telescope is contrary to the user command

WRONG LIFT RESPONSE

The boom lift is contrary to the user command

TOWER ANGLE SENSOR DISAGREE-
MENT

The tower angle sensors are reporting angles that differ too greatly.
An EMS cycle is required.

TOWER LENGTH SENSOR DIS-
AGREEMENT

The tower length sensors are reporting angles that differ too greatly.
An EMS cycle is required.

MAIN ANGLE SENSOR DISAGREE-
MENT

The main boom angle sensors are reporting angles that differ too
greatly. An EMS cycle is required.

BOOM LENGTH SENSOR #1 OUT OF
RANGE HIGH

Reported from the BLAM, indicates tower length sensor one value is
out of range high.

BOOM LENGTH SENSOR #1 OUT OF
RANGE LOW

Reported from the BLAM, indicates tower length sensor one value is
out of range low.

BOOM LENGTH SENSOR #2 OUT OF
RANGE HIGH

Reported from the BLAM, indicates tower length sensor two value is
out of range high.

BOOM LENGTH SENSOR #2 OUT OF
RANGE LOW

Reported from the BLAM, indicates tower length sensor two value is
out of range low.

TWR LENGTH SENSOR NOT
DETECTING LENGTH CHANGE

Tower tele is being commanded and the length sensors are not
changing value.

TWR LENGTH MOVEMENT WITH-
OUT CMD

Tower length is changing without a tower tele command

TWR LENGTH SENSOR ONE VALUE
OUT OF RANGE HIGH

This fault is reported by the Ground module when the length sensor
value is outside the constant data limit

TWR LENGTH SENSOR ONE VALUE
OUT OF RANGE LOW

This fault is reported by the Ground module when the length sensor
value is outside the constant data limit

Table 6-6. Help Fault Codes, Displayed Faults, and Descriptions