JLG 450A_AJ Series II Service Manual User Manual

Page 358

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-48

– JLG Lift –

3121290

3/3

(Continued)

PVG VALVE OPEN CIRCUIT

1250AJP ONLY.

PVG VALVE SHORT TO BATTERY

1250AJP ONLY.

FOX SPARE OUTPUT SHORT TO
GROUND

Fox machines ONLY.

FOX SPARE OUTPUT SHORT TO
BATTERY

Fox machines ONLY.

FOX SPARE OUTPUT OPEN CIRCUIT Fox machines ONLY.

HOUR METER OPEN CIRCUIT

This fault cannot be detected during normal operation. It may be
reported during self test.

RESTRICTED TO TRANSPORT –
AXLE LOCKOUT VALVE STB OR OC

Machines with electrically released oscillating axles configured
ONLY. A short to battery or open circuit has been detected on axle
lockout valve and machine is restricted to transport position.

RESTRICTED TO TRANSPORT –
PARKING BRAKE STB

Machines with electrically released oscillating axles configured
ONLY. A short to battery has been detected on parking brake valve
and machine is restricted to transport position.

3/4

Flash code 3/4 indicates a driver problem on a platform valve
block valve driver. All driver faults are detected in a similar man-
ner. Open circuit faults are detected when analog feedback
reads too high and output is commanded off. Short to ground is
detected when analog feedback reads low and output is com-
manded on. Short to battery is detected when analog feedback
reads Vbat and output is commanded off. Not reported during 2
second power-up. An EMS cycle is required.

6

BASKET UP SHORT TO BATTERY

BASKET UP SHORT TO GROUND

BASKET UP OPEN CIRCUIT

BASKET UP SHORT TO BATTERY OR
OPEN CIRCUIT

Machines with electronic basket leveling ONLY.

BASKET DOWN SHORT TO BATTERY

BASKET DOWN SHORT TO
GROUND

bASKET DOWN OPEN CIRCUIT

BASKET DOWN SHORT TO BATTERY
OR OPEN CIRCUIT

Machines with electronic basket leveling ONLY.

BASKET LEFT SHORT TO BATTERY

BASKER LEFT SHORT TO GROUND

BASKET LEFT OPEN CIRCUIT

BASKET RIGHT SHORT TO BATTERY

BASKET RIGHT SHORT TO GROUND

BASKET RIGHT OPEN CIRCUIT

JIB UP SHORT TO BATTERY

JIB UP SHORT TO GROUND

JIB UP OPEN CIRCUIT

JIB DOWN SHORT TO BATTERY

JIB DOWN SHORT TO GROUND

JIB DOWN OPEN CIRCUIT

JIB LEFT SHORT TO BATTERY

Table 6-6. Help Fault Codes, Displayed Faults, and Descriptions

Flash Code

Fault Displayed on Analyzer

Description

Priority