SECTION 6 - JLG CONTROL SYSTEM

3121290

– JLG Lift –

6-59

9/9

(Continued)

BLAM SENSOR SUPPLY OUT OF
RANGE HIGH

Supply voltage for boom angle sensors is above expected range. An
EMS cycle is required.

BLAM SENSOR SUPPLY OUT OF
RANGE LOW

Supply voltage for boom angle sensors is below expected range. An
EMS cycle is required.

LENGTH SENSOR REF VOLTAGE
HIGH

Supply voltage for boom length sensors is above expected range. An
EMS cycle is required.

LENGTH SENSOR REF VOLTAGE
LOW

Supply voltage for boom length sensors is below expected range.
An EMS cycle is required.

BLAM HIGH RES A/D FAILURE

High resolution analog to digital converter in the BLAM module has
failed. An EMS cycle is required.

CHASSIS SENSOR SUPPLY OUT OF
RANGE LOW

Supply voltage for chassis sensors is below expected range. An EMS
cycle is required.

CHASSIS SENSOR SUPPLY OUT OF
RANGE HIGH

Supply voltage for chassis sensors is above expected range. An EMS
cycle is required.

BLAM BACKUP COMMUNICATIONS
LINK FAULTY

Backup communications link to the BLAM failed test at startup.

BLAM BACKUP COMMUNICATIONS
LOST - HYDRAULICS SUSPENDED

Backup communications link to the BLAM module was activated but
could not establish/maintain communications with the BLAM.

4150461-E

Table 6-6. Help Fault Codes, Displayed Faults, and Descriptions

Flash Code

Fault Displayed on Analyzer

Description

Priority