Table 6-2. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.0s to 5.0s

1.0

DECELeration

0.0s to 3.0s

0.5

MINimum speed

1 to 35%

30

MAXimum speed

1 to 100%

60

REVerse MINimum speed

1 to 35%

30

REVerse MAXimum speed

1 to 100%

60

ELEVATED MAXimum speed

1 to 100%

38

CREEP MAXimum speed

1 to 90%

38

Engine RPM

800 to 2900

1800

TOWER LIFT

ACCELeration

0.0 to 5.0

1.0

DECELeration

0.0 to 3.0

1.0

MlNimum UP speed

1 to 60%

31

MAXimum UP speed

1 to 100%

47

MINimum DOWN speed

1 to 60%

28

MAXimum DOWN speed

1 to 100%

44

Engine RPM

800 to 2900

1800

MAIN LIFT

ACCELeration

0.0 to 5.0

2.0

DECELeration

0.0 to 3.0

1.0

MlNimum UP speed

1 to 60%

36

MAXimum UP speed

1 to 100%

52

CREEP Maximum UP speed

1 to 65%

45

MINimum DOWN speed

1 to 60%

29

MAXimum DOWN speed

1 to 100%

56

CREEP maximum DOWN speed

1 to 75%

49

Engine RPM

800 to 2900

1800