Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.0s to 5.0s
1.0
DECELeration
0.0s to 3.0s
0.5
MINimum speed
1 to 35%
30
MAXimum speed
1 to 100%
60
REVerse MINimum speed
1 to 35%
30
REVerse MAXimum speed
1 to 100%
60
ELEVATED MAXimum speed
1 to 100%
38
CREEP MAXimum speed
1 to 90%
38
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.0 to 5.0
1.0
DECELeration
0.0 to 3.0
1.0
MlNimum UP speed
1 to 60%
31
MAXimum UP speed
1 to 100%
47
MINimum DOWN speed
1 to 60%
28
MAXimum DOWN speed
1 to 100%
44
Engine RPM
800 to 2900
1800
MAIN LIFT
ACCELeration
0.0 to 5.0
2.0
DECELeration
0.0 to 3.0
1.0
MlNimum UP speed
1 to 60%
36
MAXimum UP speed
1 to 100%
52
CREEP Maximum UP speed
1 to 65%
45
MINimum DOWN speed
1 to 60%
29
MAXimum DOWN speed
1 to 100%
56
CREEP maximum DOWN speed
1 to 75%
49
Engine RPM
800 to 2900
1800