Lubrication chart -9, Lubrication, Engines – JLG 600SC_660SJC Service Manual User Manual

Page 21

Advertising
background image

SECTION 1 - SPECIFICATIONS

3120898

– JLG Lift –

1-9

Table 1-9. Lubrication Chart

Components

Number/Type

Lube Points

Capacity

Lube

Interval

Hours

Comments

3 Months

150 hrs

6 Months

300 hrs

1 Year

600 hrs

2 Years

1200 hrs

Lubrication

1

Swing Bearing

2 Grease Fittings

A/R

MPG

X

Remote Access

2

Swing Drive Hub

Level/Fill Plug

0.5 L (1/2 Full)

EPGL

X

Check level every 150 hrs/change 1200 hours

3

Final Drive Hub

Level/Fill Plug

7.9 L (1/2 Full)

EPGL

X

Check level every 150 hrs/change 1200 hours

4

Hydraulic Return Filter

N/A

N/A

N/A

X

Change after first 50 hrs. and every 300 hrs.
thereafter or as indicated by Condition Indica-
tor.

5

Hydraulic Charge Filter

N/A

N/A

N/A

X

Change after first 50 hrs. and every 300 hrs.
thereafter or as indicated by Condition Indica-
tor.

6

Hydraulic Oil

Fill Cap

116 L Tank

124 L System

HO

X

Check level daily/change 1200 hours

7

Suction Strainers (in
tank)

2

N/A

N/A

X

Remove and clean at time of hydraulic oil
change.

Engines

8

Oil Change w/Filter -
Deutz

Fill Cap/Spin-on Element

10.4 L Crankcase

**4.7 L Cooler

EO

X

Check level daily/Change in accordance with
engine manual.

9

Fuel Filter - Deutz

Replaceable Element

N/A

N/A

X

10

Air Filter - Deutz

Replaceable Element

N/A

N/A

X

Or as indicated by Condition Indicator.

NOTES:

KEY TO LUBRICANTS

Lubrication intervals are based on machine operation under normal
conditions. For machines used in multi shift operations and/or
exposed to hostile environments or conditions, lubrication frequen-
cies must be increased accordingly.

** When changing oil in the Deutz oil cooled engine, drain both the crankcase and
the cooler. When refilling it is acceptable to overfill the crankcase (15 L, capacity
of both crankcase and cooler combined). Start engine, allow the engine to run
until the thermostat opens (approximately 105 degrees C) cooler will fill up within
minutes; shut down and wait for approximately two minutes. Check oil level, fill oil
to max marking on the dipstick.

EO

EPGL

HO

MPG

Engine Oil
Extreme Pressure Gear Lube
Hydraulic Fluid (Mobil #424 or equivalent)
Multi-Purpose Grease

Advertising