How to make bench-static adjustments, How to make bench-static adjustments -25, Adjustment values -25 – JLG 600SC_660SJC Service Manual User Manual

Page 65: Factory defaults -25

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3120898

– JLG Lift –

4-25

RECORD THE VALUES SELECTED

When all adjustments are finalized for desired machine
performance, the values of each setting, in both directions
of joystick handle travel, should be recorded for future
use.

.

ENSURE THE MAXIMUM OUTPUT IS ADJUSTED TO 50% PRIOR
TO OPERATING THE DRIVE FUNCTION.

NOTE: When joystick is actuated the OPTIMIZER displays

direction.

How to make Bench-Static Adjustments

It is not necessary to operate any joysticks. First apply
12VDC power to the SUPERFLEX Controller. Then, con-
nect an OPTIMiZER to the SUPERFLEX using terminal
strip A.B.C.D. Adjustments can now be made.

MAKING ADJUSTMENTS

1.

Joystick/DIGISENSOR #1 [called Controller #1] is
input terminals (1) and (2).

2.

Joystick/DIGISENSOR #2 [called Controller #2] is
input terminals (3) and (4).

QUICK SUMMARY OF ADJUSTMENTS (NORMAL-
ACTIVE SET UP)

’’OPTIMIZER" Keypad Adjustment Procedure. Refer to Fig-
ure 4-30., Calibration Flow Diagram.

To make precise adjustments, the following steps are
required:

1.

Operate a Joystick.

2.

Press the desired function [Threshold, Max Out, Low
Range, Ramp up, Ramp Down].

3.

Press the [+] key to increase the function.

4.

Press the [-] key to decrease the function.

5.

When all adjustments are made in both directions
(A/B), press the "ENTER" key and the "RUN" key to
save the new settings.

Table 4-2. Adjustment Values

Joystick 1

Handle Direction

Joystick 2

Handle Direction

A

B

A

B

THRESHOLD

_____

_____

_____

_____

MAX OUT

_____

_____

_____

_____

LOW RANGE

_____

_____

_____

_____

RAMP UP

_____SEC

_____SEC

_____SEC

_____SEC

RAMP DOWN

_____SEC

_____SEC

_____SEC

_____SEC

Table 4-3. Factory Defaults

Default
Setting

Assembly

Setting

THRESHOLD

15%

15%

MAX OUT (HIGH)

85%

50%

LOW RANGE

50%

67%

RAMP UP

0

0

RAMP DOWN

0

0

Press [SELECT]

Display reads:

CONTROLLER 1 (or 2)

USE +/- TO CHANGE

Press [+] or [-]

Display reads:

CONTROLLER 2 (or 1)

Press [DIRECTION A/B]
DIR
A/B

Display will not change until a

function is selected, i.e., "Thresh-

old" display will read:
THRESHOLD 1 (or 2)

XX%, DIR A (or B)

Additional pressing + or - will

change readout accordingly

Advertising