Section 3. turntable, 1 tilt alarm switch, Manual adjustment – JLG 600SC_660SJC Service Manual User Manual

Page 31: Section 3 - turntable, Tilt alarm switch -1, Manual adjustment -1, Tilt switch adjustment -1

Advertising
background image

SECTION 3 - TURNTABLE

3120898

– JLG Lift –

3-1

SECTION 3. TURNTABLE

3.1

TILT ALARM SWITCH

PERFORM TILT ALARM SWITCH LEVELING PROCEDURE A MINI-
MUM OF EVERY SIX MONTHS TO ENSURE PROPER OPERATION
AND ADJUSTMENT OF SWITCH.

Manual Adjustment

1.

Park the machine on a flat, level surface. Ensure
machine is level and tires are filled to rated pressure.

NOTE: Ensure switch mounting bracket is level and securely

attached.

2.

Level the base of the indicator by tightening the
three flange nuts through approximately one quarter
of its spring travel. DO NOT ADJUST THE “X” NUT
DURING THE REMAINDER OF THE PROCEDURE.

3.

With the electrical connections complete, using bub-
ble level on top of indicator, slowly tighten or loosen
the three flange nuts until indicator is level.

4.

Individually push down on one corner at a time;
there should be enough travel to cause the switch to
trip. If the switch does not trip in all three tests, the
flange nuts have been tightened too far. Loosen the
“X” nut and repeat steps (2). through (4).

Figure 3-1. Tilt Switch Adjustment

Advertising