JLG 600SC_660SJC Service Manual User Manual

Page 83

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3120898

– JLG Lift –

4-43

36.

Next push the ENTER key, this will now show you
the SET POINT ADJUSTMENT setting on the dis-
play, the default setting will blink now letting you
know you can adjust.

37.

Next push the ENTER key, this will now show you
the LOAD SHED RAMP setting on the display, the
default setting will blink letting you know you can
adjust.

38.

Next push the ENTER key, this will now show you
the LOAD RESUME RAMP settings on the display,
the default display will blink letting you know you
can adjust.

39.

Next push the ENTER key, this will show the SHED
HYSTERESIS setting on the display, the default set-
ting will blink letting you know you can adjust.

Advertising