8 rotator - helac, Disassembly, Rotator - helac -17 – JLG 600SC_660SJC Service Manual User Manual

Page 57: Disassembly -17, Removing portion of end cap -17, Heating setscrew -17, Removing setscrew -17, Removing end cap -17

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3120898

– JLG Lift –

4-17

4.8

ROTATOR - HELAC

Disassembly

1.

Place actuator on a clean workbench.

2.

Remove all hydraulic fittings.

3.

Using a suitable hammer and chisel remove the por-
tion of end cap securing setscrew.

4.

Using a torch, apply heat to the setscrews on the
bottom of actuator.

5.

Remove the two (2) setscrew (4) from bottom of
actuator (1). Discard setscrew.

6.

Place two (2) 3/8"x16NC bolts in threaded holes in
bottom of the actuator. Using a suitable bar, unscrew
the end cap (5). Remove the end cap from actuator
(1).

Figure 4-20. Removing Portion of End Cap

Figure 4-21. Heating Setscrew

Figure 4-22. Removing Setscrew

Figure 4-23. Removing End Cap