SECTION 4 - BOOM & PLATFORM

4-44

– JLG Lift –

3120898

40.

Next push the ENTER key, this will show you the
RESUME HYSTERESIS setting on the display, the
default setting will blink letting you know that you
can adjust.

41.

Next push the ENTER key, this will show the SENSI-
TIVITY settings on the display, the default settings
will blink letting you know you can adjust.

42.

Next push the ENTER key this will bring you back to
the TACHOMETER mode with the new settings if
you chose to change them.

43.

Next push the (+) key this will now show you the
DS1 and DS2 settings, these are digisensor inputs
that can be tested with or without the engine run-
ning.

DEFAULT SETTINGS

TACHOMETER

Threshold

15%

Set Point Adj.

2553 (RPM)

Max Out

48%

Load Shed

3.0 seconds

Ramp Up

0.5 seconds

Load Resume Ramp

5.0 seconds

Ramp Down

0.5 seconds

Shed Hysteresis

2553 (RPM)

Low Range

70%

Resume Hysteresis

2553 (RPM)

DS1 & DS2

128%

Sensitivity

2553 (RPM)