Operation – Garland G SERIES GAS RESTAURANT RANGES User Manual

Page 10

Advertising
background image

Part # 4523104 Rev 3 (03/04/10)

Page 10

OPERATION

Caution: In the event that a binding malfunction valve or

thermostat control is observed DO NOT light the pilots or

continue operation until an authorized service technician

has inspected the appliance . Failure to do so may result in

injury .

Open Top burners

Lighting

1 . Light pilots adjacent to each burner .

2 . Turn valve completely on . Burner flame should be

1/2” (13mm) high, stable and blue in color . It should also

impinge on the bottom of a pot placed on the burner

grate .

CAUTION: Should burner ignition fail within 4 seconds, turn

the burner valve off and repeat steps 1 through 2 . If ignition

continues to fail, consult your factory authorized service

agency .

Ovens (Standard)

Lighting

1 . Lower front kick panel below oven door, raise oven

hearth bottom for easy access to oven pilot .

2 . Turn oven control knob (figure 1) to “

” position and

then push in to engage the flow of gas through the safety

device to the pilot .

Figure 1

3 . While holding knob in, light pilot with a match/BBQ

lighter or use the spark ignition (if provided) to spark

ignite pilot .

4 . Continue to hold knob in for 15 seconds after ignition,

then release . Pilot should remain lit .

5 . If pilot burner fails to light or does not stay lit, wait 5

minutes and repeat steps 2 through 4 .

6 . Replace hearth and close kick panel, then turn oven

thermostat to desired cooking temperature .

7 . To shut down main burner turn control knob (figure 1) to

” position .

Shut Down

If pilot shut down is required loosen the set screw on the

knob and remove the outer temperature thermostat knob

by carefully pulling it off . Then push in and turn the inner

control knob (figure 2) to position . The system will

disengage within 60 seconds .

Figure 2

Convection Ovens

The forced air range oven consists of a food preparation

chamber completely sealed from the combustion area .

This eliminates the possibility of contamination from flue

products and permits an efficient method of circulating the

heated air within the cooking chamber .

During the cooking process in a conventional oven, a vapor

barrier and a layer of “cool” air covers the exposed area of

the product . In a forced air oven, the fan pushes the heated

air over and around the product, sweeping away the vapor

barrier and cool air, permitting faster heat penetration . This

action permits the use of lower temperatures and shorter

cooking times .

The rule of thumb for determining the cooking temperature

is to reduce the set temperature by approximately

80°F, (28°C), from that which you would set in a conventional

oven . The product should be checked at a point midway in

the time required in a conventional oven .