Introduction, Installation – Garland G SERIES GAS RESTAURANT RANGES User Manual

Page 6

Advertising
background image

Part # 4523104 Rev 3 (03/04/10)

Page 6

INTRODUCTION

1 . Check crate for possible damage sustained during transit .

Carefully remove unit from crate and again check for

damage . Any damage to the appliance must be reported

to the carrier immediately .

2 . The wires for retaining packing material must be

removed from units . Any protective material covering

stainless steel parts must also be removed .

3 . All equipment is supplied with 6” (152mm) legs unless

specified to be dais for cove base mounting, casters

or deck mount flanged feet . Units 48” (1219mm) and

60” (1524mm) wide have legs factory mounted . Base

mounting is required when range is being installed on a

combustible floor .

4 . The type of gas and supply pressure that the equipment

was set-up for at the factory is noted on the rating plate

and on the packaging . This type of gas supply must be

used .

5 . Do not remove permanently affixed labels, warnings or

rating plates from the appliance, for this may invalidate

the manufacturer’s warranty .

Rating Plate

All burner input rates are shown on the rating plate, which is

located behind the lower front drop down panel under the

oven door .

INSTALLATION

This product has been certified as commercial cooking

equipment and must be installed by professional personnel

as specified . THIS APPLIANCE IS NOT RECOMMENDED FOR

RESIDENTIAL INSTALLATION .

We suggest installation, maintenance and repairs should

be performed by your local Garland/US Range authorized

service agency .

Siting

The floor on which the appliance is to be sited must be

capable of adequately supporting the weight of the

appliance and any ancillary equipment . Units with ovens

must be fitted with legs if installed on a combustible floor .

Adequate clearance must be provided for servicing and

proper operation .

Appliances Equipped With Casters

1 . The installation shall be made with a connector that

complies with the Standard for Connectors for Moveable

Gas Appliances, ANSI Z21 .69/CSA 6 .16, Addenda

Z21 .69B-2006/CSA 6 .16B-2006 (or latest edition), and a

quick-disconnect device that complies with the Standard

for Quick Disconnects for Use with Gas Fuel, ANSI Z21 .41/

CSA 6 .9, Addenda Z21 .41A-2005/CSA 6 .16A-2005

(or latest edition)

2 . The front casters of the appliance are equipped with

brakes to limit the movement of the appliance without

placing any strain on the connector or quick disconnect

device or its associated piping .

3 . Please be aware; required restraint is attached to a cut out

hole in side panel, and if disconnection of the restraint

is necessary, be sure to reconnect the device after the

appliance has been returned to its original position .

Appliances Equipped With Legs

1 . Raise the front of the appliance and block . Do not lay the

appliance on its back .

2 . Legs are threaded to be easily screwed into the holes

provided on the bottom of the range .

3 . Once legs have been attached and secured they can

be adjusted to level the appliance and compensate for

uneven flooring .

Advertising