2 run a test, 1 start up, Run a test – INFICON Sensistor ILS500F Leak Detection System User Manual

Page 36

Advertising
background image

36

Using the ILS500 F

ninp69e1-a (1410)

6.2

Run a Test

The ILS500 F will communicate through the lamps and messages on the display.

6.2.1

Start Up

1

Turn the ILS500 F on.

2

Wait for Ready to Start to show on the display.

3

Click Load Recipe and choose a preset recipe, or follow the instructions in the
section on page 38.

5

Tracer Gas Filling

Tracer gas filling before gas test.

6

Blockage Test

Reveals internal blockages in tested object.

Ensures that connection lines and test fixture are
correctly connected.

The test object is filled through Test Port 1 while the
pressure is recorded in Test Port 2. Practical for
testing e.g. capillaries etc.

7

Gross Leak Test 3-Gas
Pressure Decay Test

Performed in parallel with tracer gas test.

Can be used for integral testing in parallel with a more
sensitive gas test at selected points.

8

Leak detect pressurized
test object

Perform leak detection on the test object, pressurized
with tracer gas.

9

Gas Evacuation

For a fast removal of tracer gas after test. Can also
include an efficient air purge.

10

Tooling Disconnection

Disconnection of test fixture.

Step

Comment

Notice

Several of the steps are optional and can be turned off.

Chosen settings can be saved as a Recipe. For more information, see on
page 38. It is also possible to combine two recipes in one test sequence.
Contact your local supplier for more information and individual settings.

Lamp

Status

Indication

Red

ON

Acknowledge a leak.

Tested object rejected.

General error.

Green

ON

Test sequence is over (and the tested object
accepted if Leak Detector is connected.)

Yellow
(START Button)

ON

The test sequence is running.

Advertising