ALLEGRO PERISTALTIC PUMP SYSTEM TOUCHSCREEN BUTTON REFERENCE

The following buttons are part of the KDS Allegro Peristaltic Pump System software:

Settings: Access the settings menu used to

adjust the following parameters: Audible Alarms,

Pusher Block Force, Display Brightness, etc.

Fast Forward: Rotates in the forward (infuse)

direction (press & hold).

Fast Reverse: Rotates in the reverse (withdraw)

direction (press & hold).

Rate Increase: Increases dispensing rate.

Rate Decrease: Decreases dispensing rate.

Direction (RD): Reverse direction.

Direction (FD): Forward direction.

Accept: Used to accept the parameters/settings on

a screen and return to previous screen in the menu.

Cancel: Used to cancel any changes/entries on a

screen and return to the previous screen in the menu.

Set Delay Parameters: Used to set the time

values for delayed operation. This permits the

pump to start automatically at a preset time

interval.

Set Delay Parameters: Indicates the Delay

Timer has been set. The pump will start

automatically.

Run Preview: Access the Run Preview screen that

shows a summary operating parameters.

Run/Resume: Used to Run or Resume a Program.

Re-Run: Clears counters/timers (except the Total

Infused Volume counter) and runs the selected

program from the beginning.

Stop: Used to stop running a Program.

Reset: Resets all counters/timers.

Minimum Value Allowed: Used to

select minimum value allowed.

Maximum Value Allowed: Used to select

maximum value allowed.

Configure: Used to set up the program.

Back: Used to call the Mode and Programs menu.

Page Down: Used to page down in a display list.

Page Up: Used to page up in a display list.

Line Up: Used to scroll up in a display list.

Line Down: Used to scroll down in a display list.

Insert Step: Used to insert a new Step in a Program

while editing/creating the Program. The new Step is

inserted after the Step that is currently selected.

Delete Step: Used to delete the selected Step in a

Program while editing/creating the Program. To

confirm deletion, you must select the Delete Step

button a second time.

Move Step Up: Moves the currently selected Step

in a Program up one position in the Program Order

(e.g. Step 3 becomes Step 2).

Move Step Down: Moves the currently selected

Step in a Program down one position in the

Program Order (e.g. Step 2 becomes Step 3).

Copy Step: Creates a duplicate (copy) of the

currently selected Step in a Program and inserts it as

the last Step in the Program being created/edited.

Password Protection Off: Indicates that the pump

is currently unlocked. Pressing the button twice locks

the Touchpad.

Password Protection On: Indicates that the pump

is currently locked. Press the button and enter

password to unlock the Touchpad.

File Options: Access the File Options menu that is

used to manage the list of Programs and to export

Program information to an externally linked pump or

to a connected computer.