Fertilizer check valve cleaning and repair, Piston pump storage, Fertilizer check valve cleaning and repair -37 – Kinze 3660 Lift and Rotate Planter Rev. 7/14 User Manual

Page 117: Piston pump storage -37

Advertising
background image

TM

Model 3660

M0217-01

Rev. 7/11

5-37

Lubrication and Maintenance

NOTICE

Entrance of air into pump will cause rapid and severe corrosion.
KEEP AIR OUT OF PUMP!

NOTE: SUSPENSION FERTILIZER must be flushed from pump for ANY storage period.

1. Flush pump with 5 to 10 gallons of fresh water and circulate until all corrosive salts are dissolved in pump.

2. Set pump on 10. Draw in a mixture of half diesel fuel and 10 weight oil until discharge is clean. Plug inlet and
outlet.

Liquid fertilizer piston pump

PISTON PUMP STORAGE

FERTILIzER CHECK VALVE CLEANING AND REPAIR

1. Unscrew valve body and separate halves. Note direction and location of parts.

2. Clean and inspect parts. Flush with clean water. Replace damaged parts.

3. Reassemble exactly as shown. O-ring and valve seat must be firmly in place inside each half of valve body.

Direction of flow

Valve seat

Valve ball

Guide

O-ring

Spring