Tractor driven pto pump and oil cooler option, Tractor driven pto pump and oil cooler option -15 – Kinze 3660 Lift and Rotate Planter Rev. 7/14 User Manual

Page 95

Advertising
background image

TM

Model 3660

M0217-01

Rev. 7/11

5-15

Lubrication and Maintenance

Drain reservoir, clean strainer and change filter annually.

1. Disconnect suction line (hose between reservoir and pump) from reservoir and drain. To fully drain tank, raise

planter to field raised position.

2. Replace filter with good quality 10 micron filter.

3. Fill system with SAE 10W-20 multigrade wide temperature range transmission hydraulic fluid. Reservoir capacity

is approximately 10 gal (37.8L).

4. Start system and run with tractor at idle and fan turned off for 1-2 minutes. Switch fan to full speed and run with

tractor at idle for 1-2 minutes.

5. Check reservoir fluid level and fill as required. Hydraulic fluid level should be within 1"-2" from top of reservoir after

pump has run and hydraulic hoses have been primed to allow fluid to expand when heated.

6. Bring tractor to PTO speed and adjust flow control to the desired vacuum level using the flow control valve lever.

TRACTOR DRIVEN PTO PUMP AND OIL COOLER OPTION

Reservoir

Filter

Strainer

Hydraulic reservoir

Vacuum fan assembly

Oil cooler

Hydraulic
motor

NOTE: Periodically check and clean oil cooler mounted on EdgeVac fan housing.