Interplant push row unit clutch sprocket, Interplant push row unit vacuum hose shutoff, Interplant push row unit clutch sprocket -8 – Kinze 3660 Lift and Rotate Planter Rev. 7/14 User Manual

Page 52: Interplant push row unit vacuum hose shutoff -8

Advertising
background image

M0217-01

Model 3660

3-8

Rev. 7/11

TM

Row Unit Operation

INTERPLANT PUSH ROW UNIT VACUUM HOSE SHUTOFF

When push row units are not used, move row unit end of 2" vacuum hose on each push row unit to storage mount
located on side of shank except for center push row unit as shown below at right.

Storage mount

Interplant vacuum hose shutoff

INTERPLANT PUSH ROW UNIT CLUTCH SPROCKET

Push row unit clutch sprocket disengages interplant
drive from push row unit drill shaft when only pull row
units are used.

DISENGAGE
Rotate knurled collar ¼ turn. Rock drill shaft slightly
using a ⅞" wrench to take pressure off of spring
loaded pins in clutch to allow pins to “pop” out,
disengaging drive.

ENGAGE
Rotate knurled collar ¼ turn and turn drill shaft with a

" wrench until drive pins engage drive sprocket.

Interplant clutch sprocket

Center push row vacuum hose storage mount

Storage mount