WING LOCK CYLINDER CIRCUIT

PRObLEM

POSSIbLE CAUSE

SOLUTION

Cylinders will not extend or

retract.

No power to solenoid valve coils.

Auxiliary switch may be ON. Must be OFF.

Check fuse at control console. Replace

fuse with 15 amp type AGC if blown.

Check for poor wire connection or

damaged wire. Repair as required.

Cylinders will not extend.

Solenoid valve coil in port V3 not

energized.

Check for power to coil. Check coil ground

wire. If OK, switch coil from port V3 with

coil from port V4. If cylinders extend but

will not retract, replace defective coil.

Solenoid valve cartridge in port V3 stuck

closed.

Switch cartridge in port V3 with cartridge

in port V4. If cylinders extend but will not

retract, replace defective cartridge.

Cylinders will not retract.

Solenoid valve coil in port V4 not

energized.

Check for power to coil. Check coil ground

wire. If OK, switch coil from port V4 with

coil from port V3. If cylinders retract but will

not extend, replace defective coil.

Solenoid valve cartridge in port V4 stuck

closed.

Switch cartridge in port V4 with cartridge

in port V3. If cylinders retract but will not

extend, replace defective cartridge.

Cylinders retract with switch off. Solenoid valve cartridge in port V4 stuck

open.

Replace solenoid valve cartridge.

Cylinders extend with switch off. Solenoid valve cartridge in port V3 stuck

open.

Replace solenoid valve cartridge.