Lubrication and maintenance – Kinze 3660 Lift and Rotate Planter Rev. 7/14 User Manual

Page 132

Advertising
background image

M0217-01

Model 3660

5-52

Rev. 7/11

TM

Lubrication and Maintenance





PLANTER MOUNTED PTO PUMP

IP1059

Jason Lucas

FOR IS737

Hoses From
Bulkhead

Edge Vac

Flow

Control

Valve

Flow Control

Valve

Hydraulic Pump

Edge Vac

Edge Vac

ASD Fan

ASD Fan

Bulkhead On Hitch

CF

CF

IN

IN

EX

EX

¼

½

¾

HYDRAULIC SCHEMATIC - OPTIONAL PTO PUMP DRIVE AND OIL COOLER SYSTEM
(PLANTER MOUNTED)

NOTICE

Failure to connect to a return with zero pressure will damage hydraulic
motor. Connect hydraulic motor case drain to a case drain return line
with zero pressure on tractor. DO NOT connect hydraulic motor case
drain to SCV outlet. Contact tractor manufacturer for specific details
on “zero pressure return”.

Advertising