Lubrication and Maintenance

ELECTRICAL CONTROL CONSOLE SCHEMATIC

NOTE: Disconnect control console from tractor battery before doing any electrical work. Keep wiring
harnesses away from high temperature areas or sharp edges. DO NOT route wiring harnesses along battery
cables. Use cable ties to keep wire harness away from moving parts on tractor and planter. be sure tractor
frame ground connections are clean to provide good electrical
contact.

FOLD

PLANT

MAIN

MARKERS

RIGHT

LEFT

OFF

RAISE

WING

LOCK

ROTATE

TONGUE

OFF

15AMP

AIR COMP.

20AMP DELAYED

DOWN PRESSURE

DECREASE

INCREASE

WORK LIGHTS

OFF

ON

OFF

FUNCTION

TM

Splice

Work Lights

Down Pressure

Plant/Fold

Raise/Wing Lock

Rotate/Tongue

+12V
From Battery

Splice

Pin W (Orange/Black)

(Purple)

(Purple/White)

Pin J (Gray)

Pin D (Blue/White)

Black
(Transformer)

Red
(Transformer)

Yellow (Backlit Panel)

Orange
(Backlit Panel)

Push Button Switch
& Transformer

Pin F (Yellow/Red)

Pin V (Blue/Black)

PIN A (Orange/Red)

Pin B (Blue/Red)

Pin O (Red)

Ground From Battery (Black)

Splice

Pin T (Black)

Pin C (Black/Red)

Rear View of Front Panel

12 Gauge Jumper

12 Gauge Jumper

Splice

Use Female Push-On Connectors

DEL.

15A

20A

Markers

3 2

1

6 5

4

3 2

1

3 2

1

3

2

1

3

2

1

3 2

1

6 5

4

Pin H (Blue)