Solenoid valve, Tongue cylinder circuit, Solenoid valve -9 – Kinze 3660 Lift and Rotate Planter Rev. 7/14 User Manual

Page 149: Tongue cylinder circuit -9

Advertising
background image

TM

Model 3660

M0217-01

Rev. 7/11

6-9

Troubleshooting

TONGUE CYLINDER CIRCUIT

PRObLEM

POSSIbLE CAUSE

SOLUTION

Tongue cylinder will not extend,

but will retract.

No power to solenoid valve coil in port V10

and/or V14. Both must be energized.

Check wiring between control console and

solenoid coils looking for damaged wires

and poor connections.

Solenoid valve coil defective.

Switch coil from port V13 with V10. If

tongue still will not extend, switch coil

from V14 with V13. It is not necessary to

remove any solenoid wire connections. All

three solenoids are normally energized

when tongue switch is energized.

Replace defective coil.

Solenoid valve cartridges in port V10 and/

or V14 stuck closed.

Switch cartridge from port V10 with

cartridge in port V13. If tongue cylinder

retracts, replace defective cartridge from

port V10. If problem continues, switch

cartridge from port V14 with cartridge in

port V13. Replace defective cartridge.

Tongue cylinder will not extend

but tongue lock cylinder extends.

Pressure relief valve in port V11 stuck

closed or pressure setting too high. (Valve

is factory set to open at 1000 PSI.)

Replace or adjust pressure relief valve. To

adjust, loosen lock nut and turn counter

clockwise to decrease pressure.

Tongue hook does not release

before tongue starts to extend.

Solenoid valve cartridge in port V11 stuck

open or pressure setting too low. (Valve is

factory set to open at 1000 PSI.)

Replace or adjust pressure relief valve. To

adjust, loosen lock nut and turn clockwise

to increase pressure.

Tongue cylinder will not retract,

but will extend.

Solenoid valve coil in port V13 defective.

Switch coil from port V13 with coil from

port V14. If coil from port V13 is bad,

tongue will extend but not retract. Replace

defective coil.

Solenoid valve cartridge in port V13 stuck

closed.

Switch cartridge from port V13 with

cartridge from port V14. If cartridge is bad,

tongue will extend but not retract. Replace

defective cartridge.

Tongue extends with switch off. Solenoid valve cartridge in port V10 and

V14 stuck open.

Replace solenoid valve cartridge.

Tongue retracts with switch off.

Solenoid valve cartridge in port V13 stuck

open.

Replace solenoid valve cartridge.

Tongue latch releases. Tongue

extends slowly while planting.

Latch cylinder or tongue cylinder leaking

internally.

Pressure check latch and tongue cylinders.

Repair leaking cylinder(s).

SOLENOID VALVE

PRObLEM

POSSIbLE CAUSE

SOLUTION

No solenoids operate.

Low voltage.

Must be connected to 12 volt DC only.

Negative ground.

Blown fuse.

Replace control console fuse with AGC-15 amp.

Battery connection.

Clean and tighten.

Wiring harness damaged.

Repair or replace.

One solenoid valve will not

operate.

Bad switch.

Replace on control panel.

Cut wire in harness.

Locate and repair.

Bad coil.

Replace.

Poor connection at coil.

Check.

Valve operating when not

energized.

Valve stem stuck open.

Replace cartridge.

O-ring leaking.

Install new O-ring kit.

Foreign material under poppet.

Remove and clean cartridge.

Advertising