Installation

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2

Electrical installation

5.2.1

Bus cable specification

The AS-i bus cable serves as ...

• external

Voltage supply

( 23)

of the Communication Unit;

• a means for data transmission to and from the inverter.

Tip!
These data are also met by several other standardised cables. An AS-i network can also be

set up with different cables. Multi-core cables (e.g. DeviceNet Thick Cable, DESINA cable/

light conductor) or busbars can be used for the setup of AS-i networks, too. In case of doubt,

consult a specialist in the planning phase.
Prefabricated system cables can be obtained from diverse manufacturers.

"Inverter Drives 8400 motec" hardware manual
Here you can find detailed information on ...

• the digital and analog inputs/outputs;
• the relay output;
• the integrated safety system (safety option);
• the wiring of the terminals.

Observe the notes and wiring instructions contained in this documentation.

Note!

Only use cables that comply with the listed specifications.

Range

Values

Cable type

Two-wire cable, insulated and shielded

Core cross-section

1.5 mm

2

Cable resistance

< 90 m/m, (f = 3 ... 20 MHz)

Inductance

400 ... 1300 nH/m

Capacitance per unit length

< 80 pF/m

Electrical master value

< 5 μS/m

Surge impedance

70 ... 140 

Group runtime

< 8.3 ns/m