Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

53

Diagnostics

LED status displays

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10

Diagnostics

For diagnosing troubled AS-i communication, LEDs can be mounted to the Communication Unit.

The LEDs, in conjunction with a transparent cover, can be procured from Lenze.
Moreover, the current bus status can be queried via code

C13211

and the internal communication

status can be queried via code

C13950

.

10.1

LED status displays

E84DG057

LED statuses for slave 1 and slave 2

Description

Green LEDs

Red LEDs

Off

Off

There is no AS-i voltage.

On

Off

Everything is alright

• AS-i communication is possible.

Off

On

The slave is switched off; data exchange with the

master is not possible.

On

On

"No data exchange"

• The Data_Exchange_Disable flag is set; data

exchange with the master is not possible.

• The IC is waiting for a "Write Parameter Request".

• The communication monitoring reports "No data

exchange" or the IC has been reset via "Watchdog

IC Reset".

Blinking (2 Hz)

On

"No data exchange"

• The slave is waiting for address assignment by the

master.

• Data exchange with the master is not possible.

Blinking (2 Hz)

Blinking (2 Hz)

Peripheral error

• A signal indicating a peripheral error is pending at

the FID input.

• The LEDs are blinking alternately.

On

Blinking (2 Hz)

Fatal peripheral error with reset

• Data sampling pulse = LOW for more than 44 μs