Parameter data transfer

CTT2: Block parameter transfer

48

Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.5

CTT2: Block parameter transfer

In the case of the CTT2 block parameter transfer, parameter sets with a fixed length of 64 bytes are

transmitted.

9.5.1

Read mode

• Acyclic read request from the master to the slave:

• Response from slave to master is OK:

Note!

In order to guarantee that a fixed data length of 64 bytes is transmitted, all the

parameters are transmitted as 32-bit values (16 x 32-bit parameters).
If required, the data lengths or formats of the parameters must be adjusted accordingly.

Parameter data smaller than 32 bits are not extended to 32 bits.

Byte

Contents / value

0

CTT2: Code

• Index 0x12 (18): Acyclic read request

1

CTT2: Index

• Index 0x20 (32): Read parameter

2

CTT2: Number of bytes

• Value depends on the master.

Byte

Contents / value

0

CTT2: Code

• Index 0x52 (82): Acyclic read request is OK.

• All the parameters were read.

1

Reserved

2

Reserved

3

Reserved

4 ... 7

Double word 1

• Value of the parameter in code

C13214/1

...

...

64 ... 67

Double word 16

• Value of the parameter in code

C13214/16