6 data transmission slave 2 (as-i profile 7.a.e), Data transmission slave 2 (as-i profile 7.a.e), Data transfer – Lenze E84DGFCA User Manual

Page 36

Advertising
background image

Data transfer

Data transmission slave 2 (AS-i profile 7.A.E)

36

Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.6

Data transmission slave 2 (AS-i profile 7.A.E)

Accessing the data bits

Bits

Signal / I/O mapping

Description / standard connection with ...

Inputs
DI0

LP_Network_Out: MCI_bState_B0

C00621/30: not connected

DI1

LP_Network_Out: MCI_bState_B1

C00621/31: not connected

DI2

Digin_bln1

The function of these inputs cannot be selected in the

»Engineer«.

Can be used to monitor the digital inputs if the Drive Unit is

in the "offline" status.

DI3

Digin_bln3

Outputs
DO0

LP_Network_In: MCI_bCtrl_B0

C00701/1: not connected

DO1

LP_Network_In: MCI_bCtrl_B1

C00701/6: not connected

DO2

LP_Network_In: MCI_bCtrl_B2

C00701/5: not connected

DO3

Reserved

Reserved for AS-i A/B addressing

Advertising