Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

45

Parameter data transfer

CTT2: Write parameter value

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.2

CTT2: Write parameter value

• Acyclic write request from master to slave:

• Response from slave to master is OK:

• Response from slave to master has failed:

Byte

Contents / value

0

CTT2: Code

• Index 0x13 (19): Acyclic write request

1

CTT2: Index

• Index 0x18 (24): Write parameter value

2

CTT2: Number of bytes

0x8 (8)

3

Index high

byte

Index = 0x5FFF (code to be written)

4

Index low

byte

5

Subindex

6

Data type / number of bytes
Bit 7 = 0

Number (4 data bytes):

• Bits 0 ... 2 = Number of valid bytes

(1 = 1 byte, 2 = 2 bytes, 3 = 3 bytes, 4 = 4 bytes)

Bit 7 must be "0". Writing the string is not supported.

7

Data byte 1 (MSB)

8

Data byte 2

9

Data byte 3

10

Data byte 4 (LSB)

Byte

Contents / value

0

CTT2: Code

• Index 0x53 (83): Acyclic write request is OK.

• Parameter value was written.

Byte

Contents / value

0

CTT2: Code

• Index 0x93 (147): Acyclic write request is not OK.

1

CTT2: Standard error code

CTT2: Standard error codes ( 51)

2

Error code (MSB)

3

Error code

4

Error code

5

Error code (LSB)

CTT2: Acyclic device error codes ( 52)