2 write mode, Write mode, Parameter data transfer – Lenze E84DGFCA User Manual

Page 50

Advertising
background image

Parameter data transfer

CTT2: Block parameter transfer

50

Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.5.2

Write mode

• Acyclic write request from master to slave:

• Response from slave to master is OK:

• Response from slave to master has failed:

• After the acyclic write request (index 0x13 (19)) has failed, the master sends error codes.
• Then the write request from master to slave with the index 0x29 (41) is repeated.
• The slave sends the parameter values in code

C13213/1...16

again.

Byte

Contents / value

0

CTT2: Code

• Index 0x13 (19): Acyclic write request

1

CTT2: Index

• Index 0x28 (40): Write parameter

2

CTT2: Number of bytes

0x41 (65)

3

Reserved

4 ... 7

Double word 1

• Value of the parameter in code

C13213/1

...

...

64 ... 67

Double word 16

• Value of the parameter in code

C13213/16

Byte

Contents / value

0

CTT2: Code

• Index 0x53 (83): Acyclic write request is OK.

• All the parameters were written.

Byte

Contents / value

0

CTT2: Code

• Index 0x93 (147): Acyclic write request is not OK.

• Read exception list (index 0x29 (41))

1

CTT2: Standard error code

CTT2: Standard error codes ( 51)

2

Error code (MSB)

3

Error code

4

Error code

5

Error code (LSB)

CTT2: Acyclic device error codes ( 52)

Note!

Faulty writing of parameter sets can change single parameters.

Advertising