Slave 1 AS-I ASIC Profile Failure [0x01bc813d]

Slave 2 AS-I ASIC Profile Failure [0x01bc813e]

Response (Lenze setting printed in bold)

Setting:

C13207/1

/

C13208/1

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• The AS-i profile read by slave 1 (via MCU) does not

correspond to the AS-i profile 7.A.5

• Module-internal switching error

• AS-i ASIC error

• Check voltage supply, wiring and terminals.

• Switch the voltage supply of the AS-i network off and

on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)

Response (Lenze setting printed in bold)

Setting:

C13207/3

/

C13208/3

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• The AS-i profile read by slave 2 (via MCU) does not

correspond to the AS-i profile 7.A.E

• Module-internal switching error

• AS-i ASIC error

• Check voltage supply, wiring and terminals.

• Switch the voltage supply of the AS-i network off and

on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)