Settings for AS-i communication in the »Engineer«

26

Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3

Settings for AS-i communication in the »Engineer«

6.3.1

Addressing the AS-i slaves

Addressing is usually carried out automatically via the master or an external addressing unit.
The AS-Interface Communication Unit uses two slaves (see

AS-i concept of the Communication Unit

( 33)

) which must be initialised with unique addresses.

The parameters for addressing the AS-i slaves can be found in the »Engineer« on the "Settings" tab.

Note!

• If the same address is used for slave 1 and slave 2, the address of slave 2 is set to '0'.
• If address '0' is assigned to slave 1 and slave 2, slave 2 is switched "offline" (basic

settings remain intact).

• The setting

C13200/x

/

C13202/x

= 64 serves to deactivate the slave (not active or

visible in the AS-i network).

Setting / parameters

Code

Slave 1: Address EPM value

C13202/1

Slave 1: Address EPM value

C13202/2

Override slave addresses

C13204

Override of the slave addresses during

initialisation

C13205