_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Module internal/watchdog error [0x01bc6010]

Drive PDO communication timeout [0x01bc6011]

Module offline [0x01bc6100]

Module PDO communication timeout [0x01bc6101]

Response (Lenze setting printed in bold)

Setting:

C01501/1

/

C01503

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Device internal MCU error

• Switch the voltage supply of the Inverter Drive 8400

motec and the AS-i network off and on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)

Response (Lenze setting printed in bold)

Setting:

C01501/2

/

C01503

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Voltage supply of the Inverter Drive 8400 motec

interrupted.

• Check wiring and terminals.

• Check whether the Inverter Drive 8400 motec is

addressable via the diagnostics interface.

• Switch the voltage supply of the Inverter Drive 8400

motec off and on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)

Response (Lenze setting printed in bold)

Setting:

C01501/1

/

C01503

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• Device internal MCU error

• AS-i voltage supply interrupted.

• Connection between the Communication Unit and

the Drive Unit defective.

• Check wiring and terminals.

• Switch the voltage supply of the AS-i network off and

on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)

Response (Lenze setting printed in bold)

Setting:

C01501/1

/

C01503

( adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• AS-i voltage supply interrupted.

• Connection between the Communication Unit and

the Drive Unit defective.

• Check wiring and terminals.

• Switch the voltage supply of the AS-i network off and

on again.

• If this error continues to occur, please contact the

Lenze service. (it might be necessary to replace the

Communication Unit.)