Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013

66

Parameter reference

Parameters relevant for AS-i communication

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13221

C13852

C13853

Parameter | Name:

C13221 | Display: Last data from master

Data type: UNSIGNED_16

Index: 11354 = 0x2C5A

Display of the last data transmitted from the master to the communication unit.
Value is bit-coded:

Bit 0 D0
Bit 1 D1
Bit 2 D2
Bit 3 D3
Bit 4 PR0
Bit 5 PR1
Bit 6 PR2
Bit 7 PR3
Bit 8 Reserved

... ...

Bit 15 Reserved

Subcodes

Info

C13221/1

Last data from master to slave 1

C13221/2

Last data from master to slave 2

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13852 | All words to standard device

Data type: UNSIGNED_16

Index: 10723 = 0x29E3

Display of process data words 1 ... 8 which are transmitted from the communication unit to the drive unit.

Subcodes 1 ... 8 display all the process data words from the communication unit.
Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13852/1

Word 1 of process data from module to standard device

...

...

C13852/8

Word 8 of process data from module to standard device

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13853 | All words from standard device

Data type: UNSIGNED_16

Index: 10722 = 0x29E2

Display of process data words 1 ... 8 which are transmitted from the drive unit to the communication unit.

Subcodes 1 ... 8 display all the process data words from the drive unit.
Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13853/1

Word 1 process data from standard device to module

...

...

C13853/8

Word 8 of process data from standard device to module

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT