3 rated data, 4 dimensions, Technical data – Lenze EMF2102IB User Manual

Page 10

Advertising
background image

Technical data

3-2

L

_^ONMObk

3.3

Rated data

2102IB.V001

2102IB.V002

2102IB.V003

Communication media

RS232 (LECOM-A)
RS485 (LECOM-B)

RS485 (LECOM-B)

Optical fibre

(LECOM-LI)

Current consumption

80 mA

60 mA

70 mA

External supply
(terminals 39/59)

V = 24 V DC
V

RMS

= 15 TO 30 V DC; W = 5 %

V

RMS

= 20 TO 25 V DC; W = 48 %; V

SS

< 35 V

2102IB.V001 / 2102IB.V002 / 2102IB.V003:

Rated insulation voltage

Type of insulation

to PE

50 V AC

no electrical isolation

for external supply (terminals 39/59)

-

no electrical isolation

for power stage

– 820X / 821X

270 V AC

basic insulation

– 822X / 8200 vector

270 V AC

double basic insulation

– 93XX

270 V AC

double basic insulation

Insulation voltages

for bus systems

for control terminals

for bus systems

– 820X / 8200 vector

(with internal supply)

-

no electrical isolation

– 8200 vector

(with external supply)

100 V AC

basic insulation

– 821X

50 V AC

electrical isolation

– 822X

270 V AC

basic insulation

– 93XX

270 V AC

basic insulation

for external bus systems

50 V AC

electrical isolation

Degree of pollution

VDE 0110 part 2 pollution degree 2

3.4

Dimensions

Fig. 3-1

Dimensions of the 2102 fieldbus module (all dimensions in mm)

Show/Hide Bookmarks