Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual

Page 46

Advertising
background image

Appendix

8-14

L

_^ONMObk

Code

Note

Name

C0249

*

LECOM code bank

(P2102)

Code bank

Code number

0

0

to

255 (Factory setting)

1

250

to

505

2

500

to

755

3

750

to

1005

4

1000

to

1255

5

1250

to

1505

6

1500

to

1755

7

1750

to

2005

8

2000

to

2255

9

2250

to

2505

10

2500

to

2755

11

2750

to

3005

12

3000

to

3255

13

3250

to

3505

14

3500

to

3755

15

3750

to

4005

The LECOM code bank ensures the compatibility with the master-system drivers according to the LECOM-A/B specification V1.0.

The maximum code number is 255. With the code bank, an offset of 250 is added to the code number.

The code bank addressing is not effective with extended code addressing (LECOM-A/B specification).

The parameter value is always set to 0 when switching on.

LECOM format: VD

C1810

*

SW labelling

(P2102)

33S2102I_xy000

Software labelling of the 2102IB fieldbus modules

x = main SW version

y = SW subversion

LECOM format: VS

C1811

*

SW generation

(P2102)

Software generation of the 2102IB fieldbus module

LECOM format: VS

C1920

Start status

(P2102)

0

QSP

1

Controller inhibit

LECOM format: VD

C1922

Monitoring selection
code

(P2102)

0

Not active

1

Controller inhibit

2

QSP (quick stop)

LECOM format: VD

C1921

Shortened response
time

(P2102)

0

Not active

1

active

LECOM format: VD

C1923

Monitoring time

(P2102)

50 to 65535ms

LECOM format: VD

C1962

Extended code No.

See fault table

Show/Hide Bookmarks

Advertising