Examples for a RECEIVE telegram

Example 1

The current speed setpoint (code number C46) is to be read with the bus address 01 at the controller.

The host sends the following RECEIVE telegram

EOT

0

1

4

6

ENQ

The controller can respond in three different ways:

STX

4

6

3

5

.

4

ETX

BCC

Valid request: The current value of the parameter C46 is 35.4 (Hz)

or

STX

4

6

?

ETX

BCC

Invalid request: A check-sum fault (parity fault) occurred during data transmission

or

STX

4

6

EOT

Invalid request: Parameter C46 does not exist in this controller.

Example 2

The current operating status (code number C68) is to be read with the bus address 25 for the
controller.
The operating status is bit-coded and transmitted in the hexadecimal format.

The host sends the following RECEIVE telegram

EOT

2

5

6

8

ENQ

The controller’s response:

STX

6

8

H

0

9

0

0

ETX

BCC

Valid request: The current value of the parameter C68 is ” 0900” . This means:

TRIP status

not active

Maximum current

not reached

Quick stop

not active

Pulse inhibit status

free

Display of the direction of rotation

CW rotation

Q

min

status

not active

Controller enable

enabled

Operating fault

did not occur

Communication error

did not occur