2 wiring via rs485 (lecom-b), Wiring via rs485 (lecom-b), Installation – Lenze EMF2102IB User Manual

Page 18: Show/hide bookmarks

Advertising
background image

Installation

4-6

L

_^ONMObk

4.4.2

Wiring via RS485 (LECOM-B)

The following figure schematically shows the connection to a host (PC or PLC) via RS485
(LECOM-B).

2101IB

RS232

RS485

2a

2b

3

4

RS485

RS485

RS485

1

S1

89

88

72

71

5939

S1

89

88

72

71

5939

S1

89

88

72

71

5939

1

Fig. 4-4

Wiring for RS485 (LECOM-B)



Interface cable RS485

‚

Optional host connection

‚

O tional host connection

a) directly RS485

) S

f

a) directly RS485
b) RS232 via interface converter 2101IB

ƒ

PC system cable

„

2101IB interface converter

Note!

We recommend the use of appropriate accessories (see chapter 8.1.3).

Please do not use any other but a shielded and twisted cable for wiring the RS485 interface
cable.

Wiring features for RS485 (LECOM-B):

Type

2102IB.V002

Communication media

RS485 (2 wires)

Network topology

Line

Possible number of controllers

31

Maximum cable length

1200 m

Maximum baud rate

19200 bit/s

Show/Hide Bookmarks