Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual
Page 45
Appendix
8-13
L
_^ONMObk
Code
Name
Note
C0067
C0161
C0168
*
[1...8]
Fault memory
(P93XX)
Fault abbreviations
LECOM fault numbers
TRIP
Warning
Message
---
0
OC1
11
OC2
12
OC5
15
OU
1020
LU
1030
LU
1030
LP1
-
OH
50
OH3
53
OH3
53
OH4
2054
OH7
2057
OH8
58
2058
OH8
58
2058
CE0
61
2061
CE1
62
2062
CE2
63
2063
CE3
64
2064
CE3
64
2064
U15
70
CCr
71
Pr0
75
Pr0
75
Pr1
72
Pr2
73
Pr3
77
Pr3
77
Pr4
78
PEr
74
PI
79
Sd2
82
2082
Sd2
82
2082
Sd3
83
2083
Sd6
86
2086
EEr
91
2091
1091
EEr
91
2091
1091
P03
153
2153
P13
163
NMAX 200
H05
105
H07
107
H10
110
H11
111
The individual faults are described in the Operating Instructions of the controller.
LECOM format: VD
C0248
*
LECOM input
selection
(P2102)
0
0 to 255
The parameter LECOM input selection ensures the compatibility with previous master-system drivers according to the LECOM-A/B
specification V1.0. This code is only fully used with 93XX, since this series uses the so-called array parameters, i. e. a code
consists of several parameters (e.g. C0039 = JOG with 15 values). Code C0248 determines the array element to be accessed. The
functionality of the input selection is simulated (before e.g. C0038).
This input is valid for all LECOM accesses; i.e. the access of a standard parameter with a LECOM input selection that is not 0
results in a fault because the addressed value does not exist.
The array element can be directly addressed via a LECOM-A/B driver as from specification V2.0. This parameter should therefore
not be used any longer.
C0248 is included in every LECOM code bank (see C0249).
The parameter value is always set to 0 when switching on.
LECOM format: VD
Show/Hide Bookmarks