Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual

Page 43

Advertising
background image

Appendix

8-11

L

_^ONMObk

Code

Name

Keypad PC

1)

Error

Cause

Remedy

C0161

*

C

*

Fault

---

0

No error

-

-

C0162

*

C0163

*

memory

ccr

71

System error

Strong interference on control cables

Shield control cables

C0163

*

C0164

*

(P82XX)

ccr

71

System error

Ground or earth loops in the wiring

C0164

*

(P82XX)

ce0

61

Communication error to
AIF

Faulty transmission of control commands
via AIF

Insert the communication module into the hand
terminal

ce1

62

Communication error to
CAN-IN1 with sync
control

CAN-IN1-object receives faulty data or
communication is interrupted

Plug-in connection - bus module

ó Check FIF

Check transmitter
Increase monitoring time under C0357/1 if

necessary

ce2

63

Communication error to
CAN-IN2

CAN-IN2-object receives faulty data or
communication is interrupted

Plug-in connection - bus module

ó Check FIF

Check transmitter
Increase monitoring time under C0357/2 if

necessary

ce3

64

Communication error to
CAN-IN1 with event or
time control

CAN-IN1-object receives faulty data or
communication is interrupted

Plug-in connection - bus module

ó Check FIF

Check transmitter
Increase monitoring time under C0357/3 if

necessary

ce4

65

BUS-OFF
(many communication
errors occurred)

Controller has received too many incorrect
telegrams via the system bus and has

been disconnected

Check whether bus terminator available
Shield control of the cables
Check PE connection
Check bus load, if necessary, reduce the baud

rate

ce5

66

CAN Time-Out

For remote parameter setting via system
bus (C0370):
Slave does not answer. Communication

monitoring time exceeded.

Check system bus wiring
Check system bus configuration

For operation with module in FIF:
Internal fault

Contact Lenze

EEr

91

External fault (TRIP-Set)

A digital signal assigned to TRIP set has
been activated

Check external encoder

H05

105 Internal fault

Contact Lenze

id1

140 Faulty parameter

identification

Motor not connected

Connect motor

LP1

32

Fault in motor phase
(TRIP)

Failure of one/several motor phase(s)

Check motor cables,check V

min

boost, connect

the motor with the corresponding power or

182 Fault in motor phase

(warning)

Motor current too low

the motor with the corresponding power or

adapt it under C0599.

LU

103

0

DC-bus undervoltage
(only message without

Mains voltage too low

Check mains voltage

0

(only message without
TRIP)

DC-bus voltage too low

Check supply cable

OC1

11

short-circuit

short-circuit

Find reason for short-circuit; check motor cable

OC1

11

short circuit

Excessive capacitive charging current of
the motor cable

Use shorter motor cables with lower charging
current

OC2

12

Earth fault

Grounded motor phase

Check motor, check motor cable

OC2

12

Earth fault

Excessive capacitive charging current of
the motor cable

Use shorter motor cables with lower charging
current

OC3

13

Overload inverter during
acceleration or short

Acceleration time too short (C0012)

Increase acceleration time

Check drive dimensioning

acceleration or short

circuit

Defective motor cable

Check wiring

Interturn fault in the motor

Check motor

OC4

14

Overload controller during
deceleration

Deceleration time set too short (C0013)

Increase deceleration time

Check size of external brake resistor

OC5

15

Controller overload in
stationary operation

Frequent and long overload

Check drive dimensioning

OC6

16

Motor overload (I

2

x t

overload)

Motor is thermally overloaded, for
instance, because of

overload)

impermissible continuous current

Check drive dimensioning

frequent or too long acceleration
processes

Check setting of C0120

Show/Hide Bookmarks