Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual

Page 40

Advertising
background image

Appendix

8-8

L

_^ONMObk

Code

Note

Name

C0150

*

Controller status word
(parameter channel) for:

Bit

820X

821X, 822X

8200 vector

Free configuration via C0417 (see

(parameter channel) for:

820X

Free configuration via C0417 (see

Operating Instructions for 8200

vector)

820X

821X

8200 vector

822X

0

Reserved

Actual parameter set
0

=

PS 1 active

1

=

PS 2 active

FREE 0 (free access)

(P2102)

1

IMP (pulse inhibit)
0

=

Pulses for power stage enabled

1

=

Pulses for power stage inhibited

2

I

max

(current limit reached)

0

=

Current limit not reached

1

=

Current limit reached

FREE 2 (free access)

3

Reserved

f

d

= f

dset

(Act. frequency =

Frequency setpoint)
0 = f

d

<> f

dset

1 = f

d

= f

dset

FREE 3 (free access)

4

f

d

= f

dset

(Act. frequency =

Frequency setpoint)
0

=

f

d

<> f

dset

1

=

f

d

= f

dset

RFG on = RFG off
(RFG input = RFG output)

0 = RFG in < > RFG out

1 = RFG on = RFG off

FREE 4 (free access)

5

Q

min

(f

d ≤

f

dQmin

)

0

=

Q

min

not active

1

=

Q

min

active

FREE 5 (free access)

6

f

d

= 0 (act. frequency = 0)

0

=

f

d

< > 0

1

=

f

d

= 0

7

Ctrl. inhibit (controller inhibit)
0

=

No controller inhibit

1

=

Controller inhibit

8 - 11

Controller status
0

=

No error

1

=

Error

Controller status
0 = Unit initialisation
1 = Autostart lock

3 = Operation inhibited
4 = Flying-restart circuit active

5 = DC injection braking active

6 = Operation enable
7 = Message active (dynamically

set pulse inhibit, e.g. at OU)

8 = Fault active

Controller status
0 = Unit initialisation
1 = Autostart lock

3 = Operation inhibited
6 = Operation enable

7 = Message active (dynamically

set pulse inhibit, e.g. at OU)

8 = Fault active

9 = Power off

12

Overtemperature warning (

J

max

- 10 °C)

0

=

No controller inhibit

1

=

Controller inhibit

Warning
0 = No warning

1 = Warning

13

U

Gmax

(DC-bus overvoltage)

0

=

No overvoltage

1

=

Overvoltage

Message
0 = No message

1 = Message

14

Direction of rotation
0

=

CW rotation

1

=

CCW rotation

FREE 14 (free access)

15

Ready for operation (no error, overvoltage or undervoltage)
0

=

Not ready for operation

1

=

Ready for operation

FREE 15 (free access)

The status word contains the most important status information in a compressed form.
LECOM format: VH

Show/Hide Bookmarks

Advertising