Technical data
3-4
L
_^ONMObk
Processing time in the controller (t3)
The processing time in the controller depends on the controller type and the code numbers. This is
shown in the following table:
Code numbers
Processing time (2102 + controller) [ms]
Series
820X
821X/8200 vector/822X
93XX
C0046, C0135
35
1)
20
20
3)
C0050, C0150
35
20
20
C0068
70
30
30
Write other code numbers
230
20
2)
20
4)
Read other code numbers
55
20
20
1)
35 ms is valid for C0001 = 3. If C0001 = 1 and you write under C0046, access is also possible. However, the processing time is prolonged
to 70 ms.
2)
For immediately following write-access procedures, the response times may be up to 50ms.
3)
The code number C0046 can only be read. Use a free code number (e. g. C0141) to select a setpoint. For this, refer to the 93XX Manual.
4)
This is a typical value. For some codes, the processing times may be longer. For this, refer to the 93XX Manual.