1 wiring via rs232 (lecom-a), Wiring via rs232 (lecom-a), Installation – Lenze EMF2102IB User Manual

Page 17: Lemoc

Advertising
background image

Installation

4-5

L

_^ONMObk

4.4.1

Wiring via RS232 (LECOM-A)

The following figure schematically shows the connection to a host (here: PC) via RS232 (LECOM-A).

LEMOC

1

S1

 PC system cable

Fig. 4-3

Wiring for RS232 (LECOM-A)

Wiring features for RS232 (LECOM-A):

Type

2102IB.V001

Communication media

RS232

Network topology

Point-to-point

Possible number of controllers

1

Maximum cable length

15 m

Maximum baud rate

19200 bit/s

Note!

We recommend the use of ready-made PC system cables for wiring (see chapter 8.1.2).

Wire the PC system cables as described:

1. Use metallic SubD connector shells and connect both ends of the screen to the connector

shells.

2. Connect the pins as follows:

Unit

Connection element

Pin-No. (name)

2102 fieldbus module

9-pole SubD plug

2 (RxD)

3 (TxD)

5 (GND)

Host (PC PLC etc )

9-pole SubD female plug

3 (TxD)

2 (RxD)

5 (GND)

Host (PC, PLC, etc.)

25-pole SubD female plug.

2 (TxD)

3 (RxD)

7 (GND)

Show/Hide Bookmarks