Appendix

8-5

L

_^ONMObk

Code

Note

Name

C0135

*

Controller control word

Bit

820X

821X, 8200 vector, 822X

C0135

Controller control word
(parameter channel) for:

820X

821X

0

JOG1, JOG2, JOG3
0

=

C0046 active

1

=

JOG1 (C0037) active

821X

8200 vector

822X

1

1

=

JOG1 (C0037) active

2

=

JOG2 (C0038) active

3

=

JOG3 (C0039) active

JOG1, JOG2, JOG3

(P2102)

2

CW/CCW (CW rotation/CCW rotation)
0

=

CW rotation

1

=

CCW rotation

3

QSP (quick stop)
0

=

QSP not active

1

=

QSP active

4

Reserved

RFG stop (stop of the ramp function
generator)

0

=

RFG stop not active

1

=

RFG stop active

5

Reserved

RFG zero (deceleration along the T

if

ramp C0013)

0

=

RFG zero not active

1

=

RFG zero active

6

Reserved

UP function for motor potentiometer
0

=

UP not active

1

=

UP active

7

Reserved

DOWN function for motor
potentiometer

0

=

DOWN not active

1

=

DOWN active

8

Reserved

9

Ctrl. inhibit (controller inhibit)
0

=

No controller inhibit

1

=

Controller inhibit

10

Reserved

11

Reserved

TRIP reset
0⇒1

Edge from 0 to 1 causes TRIP reset

12

PAR (parameter set changeover)
0

1 (= parameter set 2)

1

0 (= parameter set 1)

13

Reserved

14

DC brake (DC injection brake)
0

=

DCB not active

1

=

DCB active

15

Reserved
The control word controls the controller. It compresses and summarizes control commands in bit commands.