2 code table, Appendix, How to read the code table – Lenze EMF2102IB User Manual

Page 35: Show/hide bookmarks

Advertising
background image

Appendix

8-3

L

_^ONMObk

8.2

Code table

How to read the code table:

Code

Code number of the parameter

Leading zeros are not required.
Codes marked with

*

are only available in parameter set 1.

Name

Name of the parameter

The text in parenthesis informs whether the codes are available in the fieldbus module or the
controller:
(P2102): Parameters in the fieldbus module 2102IB
(P820X/P821X/8200 vector/822X):
Parameters in controllers 820X, 821X and 822X.

The parameters can also be set via the 8201BB keypad.
(P93XX):Parameters in the 93XX controller.
The parameters can also be set via the 9371BB keypad.

Parameters

Contents and meaning of the parameter
values

Parameters printed in bold are set by Lenze.

Code

Name

Note

C0001

Operating mode for

82XX

8200 vector

C0001

Operating mode for

82XX

8200 vector

(P82XX)

0

Control (C0135):

Terminal

Setpoint (C0046):

Terminal

(Lenze setting: 0)

1

Control (C0135): Terminal
Setpoint (C0046):

Keypad:

2

Control (C0135): Terminal

Setpoint (C0046):

Terminal

3

Control (C0135): LECOM

Setpoint (C0046):

LECOM

The operating mode defines the source which

writes on a parameter.

The keypad and LECOM always have the right to
parameterize.

LECOM format: VD

see Operating Instructions ’Vector’

C0009

*

LECOM controller
address

(P82XX)
(P93XX)

1

1 to 99

Controller address for unique address in a LECOM-A/B/LI network.

Do not set the values 00, 10, ..., 90, since they are reserved for group addressing.

LECOM format: VD

C0040

*

Controller inhibit

(P2102)

0

Controller inhibited

1

Controller enabled

Parameter C0040 is independent of operating mode C0001.

The controller can also be enable with control word C0135.

LECOM format: VD

C0043

*

TRIP reset for:

821X

8200 vector

822X

93XX

(P2102)

0

No actual fault, fault reset by overwriting with
value 0

1

Actual fault

Parameter C0043 is independent of operating mode C0001. A TRIP can also be reset using the control word C0135. (TRIP
reset for 820X, see chapter 6.4)

LECOM format: VD

C0046

*

Frequency setpoint for:

820X

(P2102)

0 to 480 Hz

LECOM format: VD

Frequency setpoint for:

821X

8200 vector

822X

(P821X/P8200 vector/P822X)

Speed setpoint for 93XX
(C0046 can only be

read.)

0 to 480 Hz
The value can be changed through the display factor C500/C501 (see Code table included in the Operating Instructions 820X,
821X and 822X).

For 93XX, the free control code C0141 is used as speed setpoint in % of n

max

if the basic configuration is C0005=1001.

LECOM format: VD