Appendix, Show/hide bookmarks – Lenze EMF2102IB User Manual

Page 47

Advertising
background image

Appendix

8-15

L

_^ONMObk

The following list shows the fault numbers which can be read under C1962:

Fault no.

Meaning

Classification

0

No fault

1

Invalid service designation

Internal fault

2

Invalid call recognition

Internal fault

3

Invalid data type

Application error in the host

4

Invalid subcode number

Application error in the host

5

Invalid code number

Application error in the host

6

Invalid general parameter

Application error in the host

7

Access error: operating status, e.g. controller inhibit

Access error

8

Access error: because operating mode C0001

Access error

9

Access error: parameter only readable

Access error

10

Access error: general

Access error

11

Data block too long

Limit value exceeded

12

Collision with other parameter values

Limit value exceeded

13

Leave value range

Limit value exceeded

14

General limit value exceeding

Limit value exceeded

17

General internal fault

Internal fault

32

General

Communication fault 2102IB <-> controller

33

Time limit exceeded

Communication fault 2102IB <-> controller

34

Frame error

Communication fault 2102IB <-> controller

35

Parity error

Communication fault 2102IB <-> controller

36

Overflow

Communication fault 2102IB <-> controller

37

Handshake

Communication fault 2102IB <-> controller

38

Block memory overflow

Communication fault 2102IB <-> controller

208

Frame error

Communication fault controller <-> 2102IB

209

Overflow error

Communication fault controller <-> 2102IB

210

Check-sum fault in the 2102IB fieldbus module detected

Communication fault controller <-> 2102IB

211

Telegram interruption

Communication fault controller <-> 2102IB

212

Invalid data

Communication fault controller <-> 2102IB

213

Invalid service

Communication fault controller <-> 2102IB

214

Parity error

Communication fault controller <-> 2102IB

Show/Hide Bookmarks